IEC 60502-1 / 60502-2  ·  SWA, Steel Wire & AWA Armoured Cable Manufacturer
ZMS Cable logo
Home / Products / Steel Wire Armoured Cables / Steel Wire Armoured MV Cable
6/10 – 18/30 kV · Steel wire armour

Steel Wire Armoured MV Cable

6/10kV to 18/30kV XLPE insulated steel wire armoured cable with copper tape screen — for buried MV feeders and vertical risers.

Rated voltage6/10, 8.7/15, 12/20, 18/30 kV
ConductorClass 2 copper or aluminium
InsulationXLPE, 3.4 – 8.0 mm depending on grade
ScreenCopper tape, overlapped
Product overview

Construction and performance

Medium voltage feeders need three things a LV cable does not: a metallic screen to control the electric field, thicker insulation, and — on buried or vertical routes — armour strong enough to carry the pull and resist impact.

This cable combines all three. XLPE insulation over a class 2 stranded conductor, a copper tape metallic screen with overlapping laps, a bedding layer, a bed of galvanised steel wires and a PVC or PE oversheath.

The steel wire bed handles tensile load on vertical drops and long pulls and adds earth-fault capacity. Where single-core construction is required, we supply the non-magnetic AWA version instead.

Key properties

  • Copper tape screen with controlled field grading
  • Steel wire bed for tensile and impact duty
  • Partial discharge tested on every drum
  • LSZH option for tunnels and indoor substations

Technical data

PropertySpecification
Rated voltage6/10, 8.7/15, 12/20, 18/30 kV
ConductorClass 2 copper or aluminium
InsulationXLPE, 3.4 – 8.0 mm depending on grade
ScreenCopper tape, overlapped
ArmourGalvanised steel wire (SWA)
OversheathPVC, PE or LSZH
Cross-section25 – 400 mm²
StandardIEC 60502-2, BS 5467 / BS 7835
Partial discharge≤ 5 pC at 1.73 U0
Voltage test3.5 U0, 5 min
Bending radius15 × overall diameter
PackingDrum, cut lengths to route
Request a Quote
Standards & applications

Built to the standard the project specifies.

Test certificates and type test reports are supplied with the drum documents.

IEC

IEC 60502-2 — Type tested construction

BS

BS 5467 — Compliance on request

BS

BS 7835 (LSZH) — Compliance on request

IEC

IEC 60228 — Compliance on request

Typical applications

  • Buried MV distribution feeders
  • Ring main units and substation interconnectors
  • Vertical risers and shaft drops
  • Wind farm and industrial park collection
  • River, bridge and jetty crossings
Engineering support

Need this cable sized for your route?

Send the laying method, soil conditions and quantity. We confirm armour, sheath and lead time in the quotation.

Request a quotation

Request this cable

Send cores, cross-section, voltage grade and quantity. We will confirm armour type, sheath and lead time.

By sending this form you agree to our privacy policy. We reply within one business day.