Armoured cable manufacturer built
to survive the trench
Steel tape, steel wire and aluminium wire armoured power and control cables from 0.6/1 kV to 18/30 kV — for direct burial, corrosive ground, mining roadways and any route where a bare cable would not last.
Armoured cable range

Armour is a mechanical decision, not an accessory
ZMS Armoured Cable is the armoured-cable arm of ZMS Cable. We build steel tape, steel wire and aluminium wire armoured power and control cables for the routes where a cable has to survive something other than clean air.
- Continuous metallic earth path through the armour
- Resists rodent attack and point loads
- Direct burial without additional protection
- LSZH options for tunnels and basements
Five armour constructions. One selection logic.
Mechanical load, corrosion grade and circuit type decide the armour. Start from the route, not from the catalogue.
View all
SWA Armoured Power
Steel tape armoured 0.6/1 kV power cables for direct burial, duct banks and any route where the cable has to survive a spade, a rodent or a loaded truck.
View range
Steel Wire Armoured
Steel wire armour for tensile load: vertical shafts, long pulls, submersible pumps, river crossings and MV feeders.
View range
AWA Armoured
Non-magnetic aluminium wire armour for single-core and AC circuits — mechanical protection without the circulating current penalty.
View range
Armoured Control
Screened and armoured control cables, 2 to 61 cores, 450/750 V — signal integrity and mechanical protection in one construction.
View range
Special Armoured
Mining, heavy corrosion, fire resistance and corrugated aluminium armour — built for the routes where a standard SWA cable would fail early.
View rangeArmour specified against the environment, not the price list.
Our engineering team matches armour type, armour cross-section and sheath compound to the laying method and the soil.
Armour matched to the route
Tape, wire, aluminium wire or corrugated aluminium — chosen against mechanical load, corrosion grade and whether the circuit is single-core.
Standards, not approximations
IEC 60502-1 / 60502-2, BS 6346, BS 5467, BS 7846 and BS 6387 constructions, with type test reports supplied on request.
Sheath and armour options
PVC, PE, LSZH and reinforced compounds; galvanised, heavy zinc and aluminium armour, so the cable fits the soil it is buried in.
Factory-direct supply
Made to your bill of quantities in Zhengzhou, drum-marked to your project reference and shipped FOB or CIF.
Built for buyers who cannot afford downtime
Cable is a small part of a project budget and a large part of its reliability. Our production and export model is built around consistent construction, clear documentation and repeatable delivery.
Routes that demand armour.
Six route types, each with a different mix of mechanical load, corrosion and circuit criticality.
Utility tunnels and duct banks
Cable carried through concrete ducts and shared utility galleries where access is rare and mechanical damage during later works is likely.
Municipal roads and lighting
Distribution feeders and street lighting circuits buried under verges and carriageways, exposed to settlement, roots and road works.
Mining roadways and shafts
Underground roadways, conveyor lines and dewatering circuits where abrasion, water and re-routing are routine.
Chemical and petrochemical plants
Process areas with acid soils, washdown, corrosive vapours and strict fire and smoke requirements.
Metro and road tunnels
Life-safety circuits that must keep working during a fire, plus feeders in confined spaces where LSZH is mandatory.
Ports, jetties and coastal works
Saline ground, tidal zones and ship-to-shore equipment where sheath and armour corrosion decide service life.



From copper rod to armoured drum
Stranding, insulation, cabling, armouring and sheathing are controlled in-house. Every drum is inspected, length-marked and packed for export.
- In-house conductor and insulation
- Armour lay length and coverage checks
- Voltage, resistance and partial discharge tests
- Drum marking to project reference
Documentation that supports the specification.
Management-system certificates and CE conformity are available for project files.
View allPractical notes for cable buyers and engineers.
Short guides on armour selection, burial practice and corrosion grades.
View all
SWA vs Steel Wire vs AWA Armour: Which One for Your Route?
Tape armour, wire armour and aluminium wire armour solve three different problems. A practical comparison for buried, vertical and single-core routes.

Direct Burial Protection: Depth, Bedding and Armour to IEC 60502-1
Bedding, backfill, warning tape and bending radius — the four details that decide whether an armoured cable survives its first decade in the ground.

Corrosion Classes for Buried Armoured Cable: When Galvanised Tape Is Not Enough
Galvanised tape, heavy zinc, aluminium wire and PE sheath — matching the armour to the soil resistivity and the water table.
Need an armoured cable that fits the route?
Send the laying method, soil or water conditions and fault level. We will recommend the armour and quote factory-direct.
Tell us the cable specification
Send the voltage grade, cores × cross-section, armour type, sheath, quantity and destination port. Our engineering team replies within one business day.

CE
ISO 14001
ISO 45001
ISO 17020
ISO 17025