Fire Resistant Armoured Cable
Mica-barrier fire resistant armoured cable, 950 °C for 90 minutes to IEC 60331, with LSZH sheath for life-safety circuits.
Construction and performance
Fire resistant cable is specified for circuits that must keep working while the building is on fire: fire pumps, smoke extraction fans, lifts, emergency lighting and alarm sounders.
The fire resistance comes from a mica tape barrier wrapped directly over each conductor, backed by XLPE or LSZH insulation, a steel tape or wire armour and an LSZH oversheath. Tested to IEC 60331 at 950 °C for 90 minutes, with the water spray and mechanical shock variants available.
The LSZH sheath keeps smoke opacity and halogen content low, which is usually a separate requirement in the same specification.
Key properties
- Circuit integrity 950 °C / 90 min
- LSZH sheath, low smoke and halogen
- Armour retains mechanical protection during evacuation
- CWZ and water spray options
Technical data
| Property | Specification |
|---|---|
| Rated voltage | 0.6/1 kV |
| Conductor | Class 2 stranded copper |
| Fire barrier | Mica tape over each conductor |
| Insulation | XLPE or LSZH |
| Armour | Galvanised steel tape or wire |
| Oversheath | LSZH, low smoke |
| Fire test | IEC 60331-21, 950 °C / 90 min |
| Optional tests | BS 6387 CWZ, BS 8491, water spray |
| Smoke / halogen | IEC 61034, IEC 60754 |
| Cross-section | 1.5 – 240 mm² |
| Standard | IEC 60502-1, BS 7846 |
Built to the standard the project specifies.
Test certificates and type test reports are supplied with the drum documents.
IEC
IEC 60331-21 — Compliance on request
BS
BS 6387 CWZCompliance on request
BS
BS 7846 — Compliance on request
IEC
IEC 61034 / 60754 — Compliance on request
Typical applications
- Fire pump and sprinkler supplies
- Smoke extraction and pressurisation fans
- Emergency lighting and alarm circuits
- Lift and evacuation systems
- Tunnel and metro life-safety circuits
Drums planned against the container.
Drum marking, cable print and drum size are confirmed against your project reference before production.
Drums of 500 m and 1000 m as standard, or cut to your bill of quantities. Drum marking, cable print and drum size are confirmed against your project reference and the container plan before production.
- 500 m and 1000 m drums as standard
- Cut lengths to bill of quantities
- Drum marking to project reference
- FOB, CIF or DAP terms
Other constructions for the same project.
Compare armour type, sheath and voltage grade before you specify.

SWA LV Power Cable
0.6/1kV steel tape armoured PVC or XLPE power cable for direct burial — 1 to 5 cores, 1.5 to 630 mm², IEC 60502-1 and…
View details →
Steel Wire Armoured MV
6/10kV to 18/30kV XLPE insulated steel wire armoured cable with copper tape screen — for buried MV feeders and vertical…
View details →
AWA Armoured Cable
Non-magnetic aluminium wire armour for single-core and AC circuits — 0.6/1kV, 16 to 630 mm², IEC 60502-1.
View details →Need this cable sized for your route?
Send the laying method, soil conditions and quantity. We confirm armour, sheath and lead time in the quotation.
Request this cable
Send cores, cross-section, voltage grade and quantity. We will confirm armour type, sheath and lead time.