Heavy Duty Corrosion Resistant Armoured Cable
PE-sheathed armoured cable for coastal, chemical and wet burial — galvanised or aluminium armour with a 480 h salt spray option.
Construction and performance
A standard PVC-sheathed armoured cable will survive a normal trench for decades. Put it in saline ground, under a chemical plant or in a tidal zone and the sheath is the part that fails first — then the armour goes, and the cable is finished.
This construction changes both layers: heavy zinc coating (or aluminium wire) on the armour, and a black PE or LSZH oversheath with low water absorption and high resistance to acids, alkalis and chloride attack.
We test to 480 h neutral salt spray on request and can supply the sheath compound and armour coating to a project specification, including corrugated aluminium for continuous metallic screening.
Key properties
- PE oversheath with low water absorption
- Heavy zinc or aluminium armour options
- 480 h salt spray testing available
- Corrugated aluminium armour for screening
Technical data
| Property | Specification |
|---|---|
| Rated voltage | 0.6/1 kV (MV on request) |
| Conductor | Copper or aluminium |
| Insulation | XLPE or PVC |
| Armour | Heavy galvanised steel wire/tape or aluminium |
| Oversheath | Black PE, LSZH or special compound |
| Corrosion test | 480 h neutral salt spray (option) |
| Service temperature | -40 °C to +90 °C (PE sheath) |
| Standard | IEC 60502-1, IEC 60811 (sheath tests) |
| Cross-section | 2.5 – 400 mm² |
| Packing | Drum, cut lengths |
Built to the standard the project specifies.
Test certificates and type test reports are supplied with the drum documents.
IEC
IEC 60502-1 — Type tested construction
IEC
IEC 60811 — Compliance on request
IEC
IEC 60068-2-52 (salt mist) — Compliance on request
BS
BS 6346 — Compliance on request
Typical applications
- Coastal and tidal burial
- Chemical and petrochemical plants
- Water treatment and pumping stations
- Ports, jetties and offshore yards
- Saline or contaminated ground
Drums planned against the container.
Drum marking, cable print and drum size are confirmed against your project reference before production.
Drums of 500 m and 1000 m as standard, or cut to your bill of quantities. Drum marking, cable print and drum size are confirmed against your project reference and the container plan before production.
- 500 m and 1000 m drums as standard
- Cut lengths to bill of quantities
- Drum marking to project reference
- FOB, CIF or DAP terms
Other constructions for the same project.
Compare armour type, sheath and voltage grade before you specify.

SWA LV Power Cable
0.6/1kV steel tape armoured PVC or XLPE power cable for direct burial — 1 to 5 cores, 1.5 to 630 mm², IEC 60502-1 and…
View details →
Steel Wire Armoured MV
6/10kV to 18/30kV XLPE insulated steel wire armoured cable with copper tape screen — for buried MV feeders and vertical…
View details →
AWA Armoured Cable
Non-magnetic aluminium wire armour for single-core and AC circuits — 0.6/1kV, 16 to 630 mm², IEC 60502-1.
View details →Need this cable sized for your route?
Send the laying method, soil conditions and quantity. We confirm armour, sheath and lead time in the quotation.
Request this cable
Send cores, cross-section, voltage grade and quantity. We will confirm armour type, sheath and lead time.